Discover the Benefits of Using an IP Speaker for Clearer Announcements
Discover the Benefits of Using an IP Speaker for Clearer Announcements
Blog Article
Network PA System for tool to large-scale projects
Intro
The XC-9000 system is a fully digital network PA system based on the TCP/IP method. By leveraging the TCP/IP procedure, the system guarantees the reliable and appropriate transmission of all information packets. Not only can it utilize existing local area network, such as LANs or the Net, to transmit broadcast signals, yet likewise it can likewise be released on a committed broadcasting network.
The server is extremely effective. Even when linked with a a great deal of terminals, it can at the same time manage the very same job smoothly. A single-server system can support as much as 3000 terminals and enables web server plunging. There are no restrictions on the concurrent program networks, accomplishing true full electronic broadcasting
.
System Qualities
Adaptable PA System Layout
The PA system architecture is simple, consisting of service management software application, network microphones, network amplifiers, network audio speakers, and various other devices.All devices is connected using the TCP/IP intranet method, permitting flexible configuration and very easy monitoring of the system, with complimentary control over program material, network devices, and areas with the network.
Comprehensive Audio Management
The audio management software consists of integrated functions for developing broadcast strategies, flexible zoning, and pre-scheduled broadcasts.It sustains 24-hour shows, permitting altering settings throughout all the time
Versatile Audio Source Assistance
The system supports various types of audio sources for sending out notices like online speech and BGM playback. Sound sources can come from digital musical applications, CD/DVD gamers, microphones, etc. Furthermore, the system supplies diverse functions of sustaining different broadcasting functions such as set up broadcasting, zoned broadcasting, and emergency broadcasting.
Smoke Alarm System Integration
The system has an emergency alarm function and can be incorporated right into a smoke alarm system. When the alarm system central unit receives the startling signals, the cord will send the signal to devices, which sets off the XC-9000, sending signals to audio speakers
Customers might choose to pre-programmed settings to trigger full-area or zoned alarm systems in emergencies. The alarm system voices been available in multiple forms and might be modified satisfying requirements. As an example, individuals can transform language setups, upload and modify their audio sources according to exact demands, such as intruding alarm systems, emergency alarm or air aid alarm systems, etc
Emergency Alarm System Integration
The system has a smoke alarm function and can be integrated right into an emergency alarm system. When the alarm system main device receives the worrying signals, the cord will certainly send the signal to tools, which sets off the XC-9000, sending out signals to audio speakers
Customers can pick to pre-programmed settings to trigger full-area or zoned alarm systems in emergency situations. The alarm system voices can be found in multiple types and might be modified dealing with requirements. Individuals can transform language setups, upload and edit their audio resources according to specific requirements, such as intruding alarms, fire alarm systems or air help alarm systems, etc.
Application Control for System Procedures
The system enables mobile app login and usage, allowing customers to initiate broadcasts and other procedures to licensed terminals through the server software program, guaranteeing a hassle-free and structured experience.
Integrated SIP Compatibility
The system not only enables SIP phones to log in, yet additionally can be linked to third-party SIP server or IPPBX, which establishes an entirely incorporated and compatible communication system with smooth combination right into existing systems.
Open SDK
When large project like smart park takes place, the system offers an open SDK incorporated right into third-party application platforms - IP PA System
System Infrastructure
Main Features
Scheduled Playback
The system is able to instantly transmit according to the set up jobs as long as individuals submit the audio declare each period of the day to the web server and develop a playback routine.
Zone Broadcasting
The system can arbitrarily split a couple of network devices into different areas to play specified audio programs or send out statements to any type of marked location. The quantity of each tool can be from another location readjusted.
Real-time Broadcasting
The system can catch and broadcast radio programs or various other exterior audio sources in real-time, and at the very same time transmitted them in sync.
Fire Alarm Combination
The system can be integrated with the emergency alarm system for control. When an emergency alarm signal is set off, it immediately activates the emergency situation broadcast feature and supports nearby flooring alarm systems. It additionally enables manual emergency broadcasting by clicking a solitary button.
SIP Phone Combination
The system can be integrated with SIP servers, enabling real-time speech of voice broadcasting through SIP phones to send out news anytime and anywhere.
CCTV Assimilation
The electronic devices such as IP POE Audio speakers takes on the global basic ONVIF procedure, which allows their voices to be relayed using VMS systems. The terminals can additionally be incorporated with CCTV systems for synchronized program.
Key Products
Sound Administration Software Program XC-9000
B/S architecture, supports cross-platform applications.
Covers standard broadcasting system operates, allowing for dividers monitoring.
Unified management of terminals within the system, viewing job condition, and batch quantity modification, etc.
Supports building multi-level server styles, releasing management according to individual geographical regions.
Provides SDK advancement bundles for second development and assimilation with various other system platforms.
Network Paging Console XC-9038N
Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Operating Temperature level: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.
Network Paging Console XC-9037N
Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Running Temperature level: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.
Network Horn Audio Speaker GEN-6391A03
Power Supply: DC24V/2.7 A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Intercom: Supported, Integrated Microphone.
Operating Temperature: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.
Network Ceiling Audio Speaker GEN-6211A03
Power Supply: DC 24V/1A go to this site or POE.
Interaction Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Running Temperature level: -20 to 50 ° C.
Capacities: φ213 x 165mm.
Network Wall Surface Mount Speaker GEN-6011A03
Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Operating Temperature: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.
Network Column Speaker GEN-6191A03
Power Supply: DC24V/1A or POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Frequency Response: 45Hz~ 18KHz.
Running Temperature level: -10~ 55 ℃.
Measurements: 296x140x130mm.
Network Audio Bridge GEN-3101A01
Power Supply: POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Feedback: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Dimensions: 126x66x27mm.
Network Digital Amplifier XC-9508P
Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 60Hz~ 18KHz.
Running Temperature: -10~ 50 ℃.
Measurements: 440x300x44mm.
Zone Combining Digital Amplifier NBS-2301
Power Supply : A/C 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Procedure : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Action :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 site link ℉)
Measurements : 483x430x88mm.
IP User Interface Device NAC-5003
Power Supply: AC100V~ 240V, 50/60Hz.
Communication Method: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm results.
Running Temperature: -10~ 50 ℃.
Dimensions: 483x259x44mm.
Option For College
Flexible Zoning Broadcast:
The fully network terminals can recognize adaptable zoning choices, enabling relaying notifications to private terminals or various areas ( devices).
Institution Bell System:
It supplies school bell system at the beginning/ending of the course - SPON Communications. Numerous situations can be made, including various set up program jobs according to summer/winter schedule
Fire Alarm System Integration
It sustains combination with smoke alarm systems, enabling emergency alarm signals to be incorporated right into the PA system.
Classroom Audio Boosting
Terminals support daily applications in classroom scenes. They can be linked to projectors or interactive white boards for audio boosting.
Smart Road Lamp/Security Pole
Assistance SIP Method:
Integrated SIP method for smooth assimilation with network interaction systems.
VMS Operatings Systems Integration:
Integrated ONVIF method for assimilation with VMS systems.
Third-Party Integration:
Built in HTTP API for assimilation with 3rd party platforms.
Voice Alarm Causing:
Constructed in alarm system input user interface for triggering voice alarm systems with video cameras.
Solution For Resort
Zone Control by Flooring:
The system uses full network setups, splitting zones counting on different floors and control over each zone independently.
Smoke Alarm Assimilation:
The system can be incorporated with emergency alarm system, making it possible for integration of smoke alarm signals into the broadcasting system.
Scheduled Broadcasting:
It sustains programmable arranged broadcasting, permitting flexible plans according to numerous demands.
Emergency situation Broadcasting:
It supports emergency broadcasting for the whole location, allowing one-click emergency interaction.
Solution For Factory
Area Broadcasting:
It permits relaying to any type of area, ensuring no disturbance in between various areas.
Alarm system Triggering:
Terminals have different kinds of interfaces, enabling to set off alarm systems when gotten in touch with cameras.
All Network Devices:
Release of totally network tools considerably minimizes the trouble of operating such as examining tools on dangerous sites, and thus protecting individuals and property.
The deployment of all network devices significantly minimizes the trouble of procedure and maintenance administration
Integrated SIP Phones:
The system can be integrated with SIP phone and program alerts using SIP phones at any type of time and anywhere. Two-way sound talkback between SIP phones hop over to here and IP POE Audio speakers makes it simple for inspecting gadgets sitting in office or other workplaces.
The XC-9000 system is a completely digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP method, the system makes certain the proper and reliable transmission of all information packets. The system supports numerous kinds of audio resources for sending notifications like real-time speech and BGM playback. In enhancement, the system supplies diverse functions of sustaining different broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.
The system can be incorporated with the fire alarm system for control.
Report this page